Review



cesi software  (MathWorks Inc)


Bioz Verified Symbol MathWorks Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    MathWorks Inc cesi software
    Schematic diagram of the study. A: patients; B: body <t>surface</t> <t>ECG</t> collected pre-surgically including the arrhythmias; C: CT scan with torso and cardiac geometry; D: EP study with catheter ablation by intra-cardiac mapping technique; E: BSPM of the ectopic beats isolated from the ECG recording. F: boundary element model constructed according to the CT geometry; G: 3D co-registration of CARTO geometry and CT endocardium; H: <t>CESI</t> activation in 3D; I: quantitative comparisons between the CARTO mapped activation pattern and the CESI activation pattern on corresponding regions.
    Cesi Software, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/cesi software/product/MathWorks Inc
    Average 90 stars, based on 1 article reviews
    cesi software - by Bioz Stars, 2026-04
    90/100 stars

    Images

    1) Product Images from "Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients with Premature Ventricular Contractions"

    Article Title: Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients with Premature Ventricular Contractions

    Journal: IEEE transactions on bio-medical engineering

    doi: 10.1109/TBME.2017.2758369

    Schematic diagram of the study. A: patients; B: body surface ECG collected pre-surgically including the arrhythmias; C: CT scan with torso and cardiac geometry; D: EP study with catheter ablation by intra-cardiac mapping technique; E: BSPM of the ectopic beats isolated from the ECG recording. F: boundary element model constructed according to the CT geometry; G: 3D co-registration of CARTO geometry and CT endocardium; H: CESI activation in 3D; I: quantitative comparisons between the CARTO mapped activation pattern and the CESI activation pattern on corresponding regions.
    Figure Legend Snippet: Schematic diagram of the study. A: patients; B: body surface ECG collected pre-surgically including the arrhythmias; C: CT scan with torso and cardiac geometry; D: EP study with catheter ablation by intra-cardiac mapping technique; E: BSPM of the ectopic beats isolated from the ECG recording. F: boundary element model constructed according to the CT geometry; G: 3D co-registration of CARTO geometry and CT endocardium; H: CESI activation in 3D; I: quantitative comparisons between the CARTO mapped activation pattern and the CESI activation pattern on corresponding regions.

    Techniques Used: Computed Tomography, Isolation, Construct, Activation Assay

    Examples of imaging activation sequences during ectopic beats originating from the RV (Panel A) and the LV (Panel B) in two patients. Black circles represent the last successful ablation site. The white star indicates the site of initiation localized by CESI. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.
    Figure Legend Snippet: Examples of imaging activation sequences during ectopic beats originating from the RV (Panel A) and the LV (Panel B) in two patients. Black circles represent the last successful ablation site. The white star indicates the site of initiation localized by CESI. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.

    Techniques Used: Imaging, Activation Assay

    Examples of PVC ectopic beats originating near the RV free wall (Panel A) and septum (Panel B) in two patients. Black circle represents the last ablated site recorded. The white star indicates the CESI imaged initiation. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.
    Figure Legend Snippet: Examples of PVC ectopic beats originating near the RV free wall (Panel A) and septum (Panel B) in two patients. Black circle represents the last ablated site recorded. The white star indicates the CESI imaged initiation. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.

    Techniques Used: Activation Assay



    Similar Products

    90
    MathWorks Inc cesi software
    Schematic diagram of the study. A: patients; B: body <t>surface</t> <t>ECG</t> collected pre-surgically including the arrhythmias; C: CT scan with torso and cardiac geometry; D: EP study with catheter ablation by intra-cardiac mapping technique; E: BSPM of the ectopic beats isolated from the ECG recording. F: boundary element model constructed according to the CT geometry; G: 3D co-registration of CARTO geometry and CT endocardium; H: <t>CESI</t> activation in 3D; I: quantitative comparisons between the CARTO mapped activation pattern and the CESI activation pattern on corresponding regions.
    Cesi Software, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/cesi software/product/MathWorks Inc
    Average 90 stars, based on 1 article reviews
    cesi software - by Bioz Stars, 2026-04
    90/100 stars
      Buy from Supplier

    Image Search Results


    Schematic diagram of the study. A: patients; B: body surface ECG collected pre-surgically including the arrhythmias; C: CT scan with torso and cardiac geometry; D: EP study with catheter ablation by intra-cardiac mapping technique; E: BSPM of the ectopic beats isolated from the ECG recording. F: boundary element model constructed according to the CT geometry; G: 3D co-registration of CARTO geometry and CT endocardium; H: CESI activation in 3D; I: quantitative comparisons between the CARTO mapped activation pattern and the CESI activation pattern on corresponding regions.

    Journal: IEEE transactions on bio-medical engineering

    Article Title: Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients with Premature Ventricular Contractions

    doi: 10.1109/TBME.2017.2758369

    Figure Lengend Snippet: Schematic diagram of the study. A: patients; B: body surface ECG collected pre-surgically including the arrhythmias; C: CT scan with torso and cardiac geometry; D: EP study with catheter ablation by intra-cardiac mapping technique; E: BSPM of the ectopic beats isolated from the ECG recording. F: boundary element model constructed according to the CT geometry; G: 3D co-registration of CARTO geometry and CT endocardium; H: CESI activation in 3D; I: quantitative comparisons between the CARTO mapped activation pattern and the CESI activation pattern on corresponding regions.

    Article Snippet: Triangular meshes of the realistic geometry (torso, lung, epicardium and myocardium) and ECG recordings were exported to the customized CESI software developed in Matlab 2010a (Math Works, Natick, MA).

    Techniques: Computed Tomography, Isolation, Construct, Activation Assay

    Examples of imaging activation sequences during ectopic beats originating from the RV (Panel A) and the LV (Panel B) in two patients. Black circles represent the last successful ablation site. The white star indicates the site of initiation localized by CESI. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.

    Journal: IEEE transactions on bio-medical engineering

    Article Title: Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients with Premature Ventricular Contractions

    doi: 10.1109/TBME.2017.2758369

    Figure Lengend Snippet: Examples of imaging activation sequences during ectopic beats originating from the RV (Panel A) and the LV (Panel B) in two patients. Black circles represent the last successful ablation site. The white star indicates the site of initiation localized by CESI. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.

    Article Snippet: Triangular meshes of the realistic geometry (torso, lung, epicardium and myocardium) and ECG recordings were exported to the customized CESI software developed in Matlab 2010a (Math Works, Natick, MA).

    Techniques: Imaging, Activation Assay

    Examples of PVC ectopic beats originating near the RV free wall (Panel A) and septum (Panel B) in two patients. Black circle represents the last ablated site recorded. The white star indicates the CESI imaged initiation. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.

    Journal: IEEE transactions on bio-medical engineering

    Article Title: Three-Dimensional Noninvasive Imaging of Ventricular Arrhythmias in Patients with Premature Ventricular Contractions

    doi: 10.1109/TBME.2017.2758369

    Figure Lengend Snippet: Examples of PVC ectopic beats originating near the RV free wall (Panel A) and septum (Panel B) in two patients. Black circle represents the last ablated site recorded. The white star indicates the CESI imaged initiation. The left column shows the 3D volumetric view of the myocardium activation. The cross-sections along the axial direction are presented in the middle column. In the right column, the endocardial surface is extracted from the 3D imaged activations and compared with those measured by CARTO.

    Article Snippet: Triangular meshes of the realistic geometry (torso, lung, epicardium and myocardium) and ECG recordings were exported to the customized CESI software developed in Matlab 2010a (Math Works, Natick, MA).

    Techniques: Activation Assay